| ID | CVSS | Sažetak | Zadnje ažurirano | Objavljeno |
|---|---|---|---|---|
| CVE-2019-4701 | 5.0 | IBM Security Guardium Data Encryption (GDE) 3.0.0.2 is deployed with active debugging code that can create unintended entry points. IBM X-Force ID: 171936. | 2021-07-21 11:39:00 | 2020-08-26 19:15:00 |
| CVE-2019-4692 | 5.0 | IBM Security Guardium Data Encryption (GDE) 3.0.0.2 discloses sensitive information to unauthorized users. The information can be used to mount further attacks on the system. IBM X-Force ID: 171829. | 2021-07-21 11:39:00 | 2020-08-26 19:15:00 |
| CVE-2019-4689 | 5.0 | IBM Security Guardium Data Encryption (GDE) 3.0.0.2 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensiti | 2021-07-21 11:39:00 | 2020-08-26 19:15:00 |
| CVE-2019-4686 | 5.0 | IBM Security Guardium Data Encryption (GDE) 3.0.0.2 does not set the secure attribute on authorization tokens or session cookies. Attackers may be able to get the cookie values by sending a http:// link to a user or by planting this link in a site th | 2021-07-21 11:39:00 | 2020-08-26 19:15:00 |
| CVE-2020-13767 | 4.3 | The Mitel MiCollab application before 9.1.332 for iOS could allow an unauthorized user to access restricted files and folders due to insufficient access control. An exploit requires a rooted iOS device, and (if successful) could allow an attacker to | 2021-07-21 11:39:00 | 2020-08-26 18:15:00 |
| CVE-2020-5921 | 5.0 | in BIG-IP versions 15.1.0-15.1.0.4, 15.0.0-15.0.1.3, 14.1.0-14.1.2.6, 13.1.0-13.1.3.4, 12.1.0-12.1.5.1, and 11.6.1-11.6.5.2, Syn flood causes large number of MCPD context messages destined to secondary blades consuming memory leading to MCPD failure. | 2021-07-21 11:39:00 | 2020-08-26 16:15:00 |
| CVE-2020-15486 | 3.3 | An issue was discovered on Dr Trust ECG Pen 2.00.08 devices. Because the Bluetooth LE support is implemented without a requirement for pairing or security, any attacker can access the GATT server of the device and can sniff the data being broadcasted | 2021-07-21 11:39:00 | 2020-08-26 16:15:00 |
| CVE-2020-15482 | 7.2 | An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local ne | 2021-07-21 11:39:00 | 2020-08-26 16:15:00 |
| CVE-2020-5924 | 5.0 | In BIG-IP APM versions 12.1.0-12.1.5.1 and 11.6.1-11.6.5.2, RADIUS authentication leaks memory when the username for authentication is not set. | 2021-07-21 11:39:00 | 2020-08-26 15:15:00 |
| CVE-2020-5918 | 5.0 | In BIG-IP versions 15.1.0-15.1.0.4, 15.0.0-15.0.1.3, 14.1.0-14.1.2.3, 13.1.0-13.1.3.3, 12.1.0-12.1.5.1, and 11.6.1-11.6.5.1, the Traffic Management Microkernel (TMM) may stop responding when processing Stream Control Transmission Protocol (SCTP) traf | 2021-07-21 11:39:00 | 2020-08-26 15:15:00 |
| ID | CVSS | Sažetak | Zadnje ažurirano | Objavljeno |
|---|
Stranica
/39518
Zapisa po stranici: