ID CVE-2025-22961
Sažetak A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.
Reference
CVSS
Base: 8.0
Impact: 5.9
Exploitability:2.1
Pristup
VektorSloženostAutentikacija
NETWORK LOW LOW
Impact
PovjerljivostCjelovitostDostupnost
HIGH HIGH HIGH
CVSS vektor CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Zadnje važnije ažuriranje 12-03-2025 - 19:15
Objavljeno 13-02-2025 - 23:15