| ID |
CVE-2025-11784
|
| Sažetak |
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter. |
| Reference |
|
| CVSS |
| Base: | 0.0 |
| Impact: | None |
| Exploitability: | None |
|
| Pristup |
| Vektor | Složenost | Autentikacija |
| None |
None |
None |
|
| Impact |
| Povjerljivost | Cjelovitost | Dostupnost |
| None |
None |
None |
|
| CVSS vektor |
None |
| Zadnje važnije ažuriranje |
02-12-2025 - 17:16 |
| Objavljeno |
02-12-2025 - 13:15 |