ID |
CVE-2024-43649
|
Sažetak |
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). |
Reference |
|
CVSS |
Base: | 8.8 |
Impact: | 5.9 |
Exploitability: | 2.8 |
|
Pristup |
Vektor | Složenost | Autentikacija |
NETWORK |
LOW |
LOW |
|
Impact |
Povjerljivost | Cjelovitost | Dostupnost |
HIGH |
HIGH |
HIGH |
|
CVSS vektor |
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Zadnje važnije ažuriranje |
09-01-2025 - 15:15 |
Objavljeno |
09-01-2025 - 08:15 |