ID CVE-2023-39463
Sažetak Triangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the trusted certification feature. The issue lies in the handling of the OpcUaSecurityCertificateAuthorityTrustDir variable, which allows an arbitrary file write with attacker-controlled data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20537.
Reference
CVSS
Base: 7.2
Impact: 5.9
Exploitability:1.2
Pristup
VektorSloženostAutentikacija
NETWORK LOW HIGH
Impact
PovjerljivostCjelovitostDostupnost
HIGH HIGH HIGH
CVSS vektor CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H