CVE-2022-30275
|
| Sažetak |
The Motorola MOSCAD Toolbox software through 2022-05-02 relies on a cleartext password. It utilizes an MDLC driver to communicate with MOSCAD/ACE RTUs for engineering purposes. Access to these communications is protected by a password stored in cleartext in the wmdlcdrv.ini driver configuration file. In addition, this password is used for access control to MOSCAD/STS projects protected with the Legacy Password feature. In this case, an insecure CRC of the password is present in the project file: this CRC is validated against the password in the driver configuration file. |
| Reference |
|
| CVSS |
| Base: | 7.5 |
| Impact: | 3.6 |
| Exploitability: | 3.9 |
|
| Pristup |
| Vektor | Složenost | Autentikacija |
| NETWORK |
LOW |
NONE |
|
| Impact |
| Povjerljivost | Cjelovitost | Dostupnost |
| HIGH |
NONE |
NONE |
|
| CVSS vektor |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |