ID |
CVE-2022-29223
|
Sažetak |
Azure RTOS USBX is a USB host, device, and on-the-go (OTG) embedded stack. In versions prior to 6.1.10, an attacker can cause a buffer overflow by providing the Azure RTOS USBX host stack a HUB descriptor with `bNbPorts` set to a value greater than `UX_MAX_TT` which defaults to 8. For a `bNbPorts` value of 255, the implementation of `ux_host_class_hub_descriptor_get` function will modify the contents of `hub` -> `ux_host_class_hub_device` -> `ux_device_hub_tt` array violating the end boundary by 255 - `UX_MAX_TT` items. The USB host stack needs to validate the number of ports reported by the hub, and if the value is larger than UX_MAX_TT, USB stack needs to reject the request. This fix has been included in USBX release 6.1.10. |
Reference |
|
CVSS |
Base: | 7.5 |
Impact: | 6.4 |
Exploitability: | 10.0 |
|
Pristup |
Vektor | Složenost | Autentikacija |
NETWORK |
LOW |
NONE |
|
Impact |
Povjerljivost | Cjelovitost | Dostupnost |
PARTIAL |
PARTIAL |
PARTIAL |
|
CVSS vektor |
AV:N/AC:L/Au:N/C:P/I:P/A:P |
Zadnje važnije ažuriranje |
07-06-2022 - 16:42 |
Objavljeno |
24-05-2022 - 15:15 |