CVE-2020-12149 - CERT CVE
ID CVE-2020-12149
Sažetak The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0.
Reference
CVSS
Base: 8.5
Impact: 10.0
Exploitability:6.8
Pristup
VektorSloženostAutentikacija
NETWORK MEDIUM SINGLE
Impact
PovjerljivostCjelovitostDostupnost
COMPLETE COMPLETE COMPLETE
CVSS vektor AV:N/AC:M/Au:S/C:C/I:C/A:C
Zadnje važnije ažuriranje 12-12-2024 - 00:15
Objavljeno 11-12-2020 - 16:15