CVE-2013-2805 - CERT CVE
ID CVE-2013-2805
Sažetak Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
Reference
CVSS
Base: 7.8
Impact: 6.9
Exploitability:10.0
Pristup
VektorSloženostAutentikacija
NETWORK LOW NONE
Impact
PovjerljivostCjelovitostDostupnost
NONE NONE COMPLETE
CVSS vektor AV:N/AC:L/Au:N/C:N/I:N/A:C
Zadnje važnije ažuriranje 10-02-2020 - 21:24
Objavljeno 26-03-2019 - 18:29