Svi - CERT CVE

ID CVSS Sažetak Zadnje ažurirano Objavljeno
CVE-2020-14166 3.5 The /servicedesk/customer/portals resource in Jira Service Desk Server and Data Center before version 4.10.0 allows remote attackers with project administrator privileges to inject arbitrary HTML or JavaScript names via an Cross Site Scripting (XSS) 2022-02-01 17:41:00
CVE-2022-23027 5.0 On BIG-IP versions 15.1.x before 15.1.4, 14.1.x before 14.1.4.4, 13.1.x beginning in 13.1.3.6, 12.1.5.3-12.1.6, and 11.6.5.2, when a FastL4 profile and an HTTP, FIX, and/or hash persistence profile are configured on the same virtual server, undisclos 2022-02-01 17:40:00
CVE-2022-23011 5.0 On certain hardware BIG-IP platforms, in version 15.1.x before 15.1.4 and 14.1.x before 14.1.3, virtual servers may stop responding while processing TCP traffic due to an issue in the SYN Cookie Protection feature. Note: Software versions which have 2022-02-01 17:35:00
CVE-2022-23026 4.0 On BIG-IP ASM & Advanced WAF version 16.1.x before 16.1.2, 15.1.x before 15.1.4.1, 14.1.x before 14.1.4.5, and all versions of 13.1.x and 12.1.x, an authenticated user with low privileges, such as a guest, can upload data using an undisclosed REST en 2022-02-01 17:29:00
CVE-2022-23010 7.1 On BIG-IP versions 16.x before 16.1.0, 15.1.x before 15.1.4.1, 14.1.x before 14.1.4.4, and all versions of 13.1.x, 12.1.x, and 11.6.x, when a FastL4 profile and an HTTP profile are configured on a virtual server, undisclosed requests can cause an inc 2022-02-01 17:21:00
CVE-2022-23009 9.0 On BIG-IQ Centralized Management 8.x before 8.1.0, an authenticated administrative role user on a BIG-IQ managed BIG-IP device can access other BIG-IP devices managed by the same BIG-IQ system. Note: Software versions which have reached End of Techni 2022-02-01 17:04:00
CVE-2015-5537 4.3 The SSL layer of the HTTPS service in Siemens RuggedCom ROS before 4.2.0 and ROX II does not properly implement CBC padding, which makes it easier for man-in-the-middle attackers to obtain cleartext data via a padding-oracle attack, a different vulne 2022-02-01 16:54:00
CVE-2014-2590 5.0 The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (interface outage) via crafted HTTP packets. 2022-02-01 16:53:00
CVE-2014-1966 7.8 The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets. 2022-02-01 16:53:00
CVE-2013-6926 8.0 The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account. 2022-02-01 16:53:00
ID CVSS Sažetak Zadnje ažurirano Objavljeno
Stranica
/39518
Zapisa po stranici: