ID CVSS Sažetak Zadnje ažurirano Objavljeno
CVE-2018-7499 7.5 In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several stack-based buffer 2020-10-02 14:49:00
CVE-2019-10947 6.8 Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitra 2020-10-02 14:44:00
CVE-2018-7340 5.0 Duo Network Gateway 1.2.9 and earlier may incorrectly utilize the results of XML DOM traversal and canonicalization APIs in such a way that an attacker may be able to manipulate the SAML data without invalidating the cryptographic signature, allowing 2020-10-02 14:44:00
CVE-2019-10951 6.8 Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrar 2020-10-02 14:43:00
CVE-2019-10950 10.0 Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnera 2020-10-02 14:40:00
CVE-2019-10249 6.8 All Xtext & Xtend versions prior to 2.18.0 were built using HTTP instead of HTTPS file transfer and thus the built artifacts may have been compromised. 2020-10-02 14:37:00
CVE-2019-10922 7.5 A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network ac 2020-10-02 14:36:00
CVE-2019-10145 6.9 rkt through version 1.30.0 does not isolate processes in containers that are run with `rkt enter`. Processes run with `rkt enter` do not have seccomp filtering during stage 2 (the actual environment in which the applications run). Compromised contain 2020-10-02 14:35:00
CVE-2019-10962 5.0 BD Alaris Gateway versions, 1.0.13,1.1.3 Build 10,1.1.3 MR Build 11,1.1.5, and 1.1.6, The web browser user interface on the Alaris Gateway Workstation does not prevent an attacker with knowledge of the IP address of the Alaris Gateway Workstation ter 2020-10-02 14:34:00
CVE-2019-10966 5.0 In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuratio 2020-10-02 14:32:00